TY - JOUR
T1 - The use of touch DNA analysis in forensic identification focusing on Short Tandem Repeat-Combined DNA Index System loci THO1, CSF1PO and TPOX
AU - Yudianto, Ahmad
AU - Indah Nuraini, M.
AU - Furqoni, Abdul Hadi
AU - Manyanza Nzilibili, Simon Martin
AU - Harjanto, Pudji
N1 - Publisher Copyright:
© 2020 Genetics Society of America. All rights reserved.
PY - 2020
Y1 - 2020
N2 - Forensic identification through DNA analysis is an accurate diagnostic tool. Deoxyribonucleic Acid (DNA) analysis is via DNA repetitive regions with less than 1 kb base size is called ‘microsatellite’ or Short Tandem Repeat (STR). At the crime scene, the perpetrator’s skin may accidentally be in contact with surrounding objects, thereby transferring trace evidence to the objects. In this study DNA was obtained using “touch DNA” from two buccal smears and two smear from watches and cellphones from volunteers who had signed the consent form. Samples were isolated using DNAzol. The quantity of DNA obtained will be measured using a UV spectrophotometer. For DNA amplification using 3 STR CODIS loci namely TH01, CSF1PO, and TPOX. The last step is visualization using acrylamide gel and silver staining. Mean levels of DNA (UV-Visible Spectrophotometer) were 167.89±85.71 µg/mL for the buccal swab, 59.19±5.58 µg/mL for the watch swab, and 38.09±2.12 µg/mL for the mobile swab; the purity of the buccal swab DNA was 1.79±0.71, of the watch swab 1.69±0.76, and of the mobile swab 1.53±0.56. Visualization of PCR products on Polyacrylamide Agarose Composite Gel Electrophoresis stained with Silver and amplified using the standard primers THOI, TPOX and CSF1PO for STR Combined DNA Index System (CODIS) showed a 100% detection of amplicons. Both the buccal swab, watch swab and handphone swabs had trace amount of DNA that was sufficient to be isolated and amplified by using Polymerase Chain Reaction on the STR CODIS loci THO1, CSF1PO and TPOX.
AB - Forensic identification through DNA analysis is an accurate diagnostic tool. Deoxyribonucleic Acid (DNA) analysis is via DNA repetitive regions with less than 1 kb base size is called ‘microsatellite’ or Short Tandem Repeat (STR). At the crime scene, the perpetrator’s skin may accidentally be in contact with surrounding objects, thereby transferring trace evidence to the objects. In this study DNA was obtained using “touch DNA” from two buccal smears and two smear from watches and cellphones from volunteers who had signed the consent form. Samples were isolated using DNAzol. The quantity of DNA obtained will be measured using a UV spectrophotometer. For DNA amplification using 3 STR CODIS loci namely TH01, CSF1PO, and TPOX. The last step is visualization using acrylamide gel and silver staining. Mean levels of DNA (UV-Visible Spectrophotometer) were 167.89±85.71 µg/mL for the buccal swab, 59.19±5.58 µg/mL for the watch swab, and 38.09±2.12 µg/mL for the mobile swab; the purity of the buccal swab DNA was 1.79±0.71, of the watch swab 1.69±0.76, and of the mobile swab 1.53±0.56. Visualization of PCR products on Polyacrylamide Agarose Composite Gel Electrophoresis stained with Silver and amplified using the standard primers THOI, TPOX and CSF1PO for STR Combined DNA Index System (CODIS) showed a 100% detection of amplicons. Both the buccal swab, watch swab and handphone swabs had trace amount of DNA that was sufficient to be isolated and amplified by using Polymerase Chain Reaction on the STR CODIS loci THO1, CSF1PO and TPOX.
KW - Identification
KW - STR CODIS
KW - Touch DNA
UR - http://www.scopus.com/inward/record.url?scp=85090462392&partnerID=8YFLogxK
U2 - 10.4081/idr.2020.8716
DO - 10.4081/idr.2020.8716
M3 - Article
AN - SCOPUS:85090462392
SN - 2036-7430
VL - 12
JO - Infectious Disease Reports
JF - Infectious Disease Reports
M1 - 8716
ER -