TY - JOUR
T1 - Selective Identification for Glucose in the Presence of Fructose Using Imprinted Polyeugenol Modified Graphite Paste Electrode
AU - Djunaidi, Muhammad Cholid
AU - Gunawan, Gunawan
AU - Cahyaningrum, Lutfia
AU - Lusiana, Retno Ariadi
AU - Khasanah, Miratul
N1 - Funding Information:
The authors would like to thank the Ministry of Education and Culture for the financial support of this study through Grant No 225-69/UN7.6.1/PP/2021.
Publisher Copyright:
© 2022, Gadjah Mada University. All rights reserved.
PY - 2022
Y1 - 2022
N2 - High blood glucose levels indicate diabetes mellitus. The conventional way was carried out to determine glucose levels, but this method just shows the total reducing sugar levels. An electrode was developed to analyze glucose in the presence of fructose by potentiometry. The optimum graphite paste electrodes-Imprinted based on polyeugenol and Ethylene Glycol Dimethacrylate (EGDMA) as crosslinkers, had been used as a glucose sensor. Polyeugenol was made by the polymerization reaction with a BF3 catalyst with a molecular weight of 6451.338 g/mol. A total of 2135.99 glucose was contacted with polyeugenol, and the result was crosslinked with EGDMA and 2,2'-Azobis(2-methylpropionitrile) (AIBN) initiator, then Molecularly Imprinted Polymer (MIP) was generated. The optimization of electrodes showed that the best composition of MIP: paraffin: graphite is 20:35:45 with the 19.16 mV/decade Nernstian Factor, which can measure samples at the range 10–5–10–1 M with a detection limit of 1.0334 × 10–5 M, a response time of 6–15 s, a lifetime (use) of 19 times and has good selectivity on fructose sample with Kij less than 1. Measurements using this electrode showed that honey contains 28.78% of glucose, not much different from the UV-Vis spectrophotometry, which is 29.68%, and HPLC is 30.42%.
AB - High blood glucose levels indicate diabetes mellitus. The conventional way was carried out to determine glucose levels, but this method just shows the total reducing sugar levels. An electrode was developed to analyze glucose in the presence of fructose by potentiometry. The optimum graphite paste electrodes-Imprinted based on polyeugenol and Ethylene Glycol Dimethacrylate (EGDMA) as crosslinkers, had been used as a glucose sensor. Polyeugenol was made by the polymerization reaction with a BF3 catalyst with a molecular weight of 6451.338 g/mol. A total of 2135.99 glucose was contacted with polyeugenol, and the result was crosslinked with EGDMA and 2,2'-Azobis(2-methylpropionitrile) (AIBN) initiator, then Molecularly Imprinted Polymer (MIP) was generated. The optimization of electrodes showed that the best composition of MIP: paraffin: graphite is 20:35:45 with the 19.16 mV/decade Nernstian Factor, which can measure samples at the range 10–5–10–1 M with a detection limit of 1.0334 × 10–5 M, a response time of 6–15 s, a lifetime (use) of 19 times and has good selectivity on fructose sample with Kij less than 1. Measurements using this electrode showed that honey contains 28.78% of glucose, not much different from the UV-Vis spectrophotometry, which is 29.68%, and HPLC is 30.42%.
KW - fructose
KW - glucose
KW - imprinted
KW - polyeugenol
KW - selective electrode
UR - http://www.scopus.com/inward/record.url?scp=85136823833&partnerID=8YFLogxK
U2 - 10.22146/ijc.71013
DO - 10.22146/ijc.71013
M3 - Article
AN - SCOPUS:85136823833
SN - 1411-9420
VL - 22
SP - 913
EP - 921
JO - Indonesian Journal of Chemistry
JF - Indonesian Journal of Chemistry
IS - 4
ER -