T1 - Resilient wide-area multi-mode controller design based on Bat algorithm for power systems with renewable power generation and battery energy storage systems
AU - Setiadi, Herlambang
AU - Mithulananthan, N.
AU - Shah, Rakibuzzaman
AU - Lee, Kwang Y.
AU - Krismanto, Awan Uji
N1 - Publisher Copyright:
© 2019 The Institution of Engineering and Technology.
PY - 2019/5/21
Y1 - 2019/5/21
N2 - Modern power systems consist of power electronics devices, which are used in renewable energy (RE) conversion. However, these devices, associated controllers, and uncertainty in RE output could bring new challenges to power system stability, especially oscillatory stability. Hence, the integration of battery energy storage systems (BESSs) is being developed to minimise the uncertainty and variability in renewables. Furthermore, to tackle the complex dynamics and inertia-less characteristics of wind and PV plants additional controllers such as power oscillation damping (POD) control and virtual inertia scheme are sought. However, the primary challenges associated with the wide-area oscillation damping controller are signal transmission delay, loss of communication signal, data drops, and others. This paper proposes a bat algorithm (BA) based resilient wide-area multi-mode controller (MMC) for enhancing oscillatory stability margin with high penetration of renewable power generations (RPGs) and BESSs. The Java 500 .kV Indonesian grid is used to evaluate the performance of the resilient wide-area MMC. From the results, it is found that the proposed controller effectively damp the critical mode of oscillation in the system even under communication failure as well as certain damping controller failures.
AB - Modern power systems consist of power electronics devices, which are used in renewable energy (RE) conversion. However, these devices, associated controllers, and uncertainty in RE output could bring new challenges to power system stability, especially oscillatory stability. Hence, the integration of battery energy storage systems (BESSs) is being developed to minimise the uncertainty and variability in renewables. Furthermore, to tackle the complex dynamics and inertia-less characteristics of wind and PV plants additional controllers such as power oscillation damping (POD) control and virtual inertia scheme are sought. However, the primary challenges associated with the wide-area oscillation damping controller are signal transmission delay, loss of communication signal, data drops, and others. This paper proposes a bat algorithm (BA) based resilient wide-area multi-mode controller (MMC) for enhancing oscillatory stability margin with high penetration of renewable power generations (RPGs) and BESSs. The Java 500 .kV Indonesian grid is used to evaluate the performance of the resilient wide-area MMC. From the results, it is found that the proposed controller effectively damp the critical mode of oscillation in the system even under communication failure as well as certain damping controller failures.
KW - battery storage plants
KW - control system synthesis
KW - damping
KW - optimisation
KW - power grids
KW - power system control
KW - power system measurement
KW - power system stability
KW - renewable energy sources
UR - http://www.scopus.com/inward/record.url?scp=85067209684&partnerID=8YFLogxK
U2 - 10.1049/iet-gtd.2018.6384
DO - 10.1049/iet-gtd.2018.6384
M3 - Article
AN - SCOPUS:85067209684
SN - 1751-8687
VL - 13
SP - 1884
EP - 1894
JO - IET Generation, Transmission and Distribution
JF - IET Generation, Transmission and Distribution
IS - 10
ER -