TY - JOUR
T1 - Network meta-analysis comparison of Hydrus, Istent microinvasive glaucoma surgery implants, and phacoemulsification for handling open-angle glaucoma
AU - Anjaswari, Niska Ayu
AU - Primitasari, Yulia
AU - Wungu, Citrawati Dyah Kencono
AU - Komaratih, Evelyn
AU - Sasono, Wimbo
AU - Sulistiawati,
N1 - Publisher Copyright:
© 2024 by the authors; licensee Learning Gate.
PY - 2024
Y1 - 2024
N2 - This study aims to analyze the comparative effectiveness of two Microinvasive Glaucoma Surgery (MIGS) devices, Hydrus and iStent, in combination with phacoemulsification in patients with open-angle glaucoma. The protocol for this network meta-analysis registered in PROSPERO under registration number CRD42023404273. Literature search was conducted following PRISMA guidelines. RCTs were retrieved from multiple databases based on inclusion and exclusion criteria. Evaluated parameters included intraocular pressure, visual acuity, the number of postoperative anti-glaucoma medications, and complications. Mean probability for each treatment was obtained using SUCRA. Ten selected articles originating from America and Europe with varying follow-up periods. SUCRA analysis shows that the combination of Hydrus and phacoemulsification ranks highest in reducing IOP at 92.38%, compared to the combination of iStent and phacoemulsification at 56.99%, and phacoemulsification only at 0.62%. The best outcomes for post-intervention BCVA ≥ 20/40 are reported in the SUCRA diagram (63.88%), as well as for the best post-intervention medication use (85.5%) and minimal complications (86.41%), which were observed in combination of iStent and phacoemulsification. The Hydrus combination intervention showed the greatest reduction in IOP, while the iStent combination more effective in improving visual acuity and reducing postoperative anti-glaucoma medication use and had the fewest overall postoperative complications. This study highlights that MIGS interventions, particularly Hydrus and iStent combined with phacoemulsification, offer significant benefits and show more effective compared to standalone phacoemulsification.
AB - This study aims to analyze the comparative effectiveness of two Microinvasive Glaucoma Surgery (MIGS) devices, Hydrus and iStent, in combination with phacoemulsification in patients with open-angle glaucoma. The protocol for this network meta-analysis registered in PROSPERO under registration number CRD42023404273. Literature search was conducted following PRISMA guidelines. RCTs were retrieved from multiple databases based on inclusion and exclusion criteria. Evaluated parameters included intraocular pressure, visual acuity, the number of postoperative anti-glaucoma medications, and complications. Mean probability for each treatment was obtained using SUCRA. Ten selected articles originating from America and Europe with varying follow-up periods. SUCRA analysis shows that the combination of Hydrus and phacoemulsification ranks highest in reducing IOP at 92.38%, compared to the combination of iStent and phacoemulsification at 56.99%, and phacoemulsification only at 0.62%. The best outcomes for post-intervention BCVA ≥ 20/40 are reported in the SUCRA diagram (63.88%), as well as for the best post-intervention medication use (85.5%) and minimal complications (86.41%), which were observed in combination of iStent and phacoemulsification. The Hydrus combination intervention showed the greatest reduction in IOP, while the iStent combination more effective in improving visual acuity and reducing postoperative anti-glaucoma medication use and had the fewest overall postoperative complications. This study highlights that MIGS interventions, particularly Hydrus and iStent combined with phacoemulsification, offer significant benefits and show more effective compared to standalone phacoemulsification.
KW - Human Medicine
KW - MIGS
KW - Open-angle glaucoma
KW - Phacoemulsification
UR - http://www.scopus.com/inward/record.url?scp=85214840007&partnerID=8YFLogxK
U2 - 10.55214/25768484.v8i6.3680
DO - 10.55214/25768484.v8i6.3680
M3 - Article
AN - SCOPUS:85214840007
SN - 2576-8484
VL - 8
SP - 7726
EP - 7749
JO - Edelweiss Applied Science and Technology
JF - Edelweiss Applied Science and Technology
IS - 6
ER -