Abstract
Hospitals as a place of health care and workplace have a variety of poten-tial hazards that can harm health. One of the efforts of the hospital environment that can be done by conducting supervision and inspection. The purpose of this research, to describe the risk factors of biological contaminants in the environmental test results conducted in Surabaya General Hospital "Y". This research was a descriptive research with a cross sectional approach. This research uses secondary data of the laboratory test results of BBTKLPP Surabaya in 2015-August 2017, as well as literature from seve-ral sources to support the data available. Data was analyzed in a descriptive and presented in the form of tables and graphs. The results of biological examinations on air space, food and beverage, medical device swab, air conditioner, and clean water in unqualified conditions. Only the quality of the wall swab and floor can be said to be good and qualified. Public hospital "Y" Surabaya is still not qualified in terms of quality microbiology test based on decree of the Minister of Health of Republic of Indonesia number 1204 year 2014 on health requirements of hospital environment. Thorough evaluation is necessary to improve the quality of microbiology in the environment in the hospital Y Surabaya, especially in areas with high risk such as surgical room and ICU.
Translated title of the contribution | Risk Factor Description of Biological Contaminants on Environmental Test Parameters in ”Y” General Hospital Surabaya |
---|---|
Original language | Indonesian |
Pages (from-to) | 204-215 |
Number of pages | 12 |
Journal | Media Kesehatan Masyarakat Indonesia |
Volume | 16 |
Issue number | 2 |
DOIs | |
Publication status | Published - Jun 2020 |
Keywords
- Hospital
- microbiological
- risk factors