TY - JOUR
T1 - DEVELOPMENT OF MULTI FREQUENCY ELECTRICAL IMPEDANCE TOMOGRAPHY FOR RECTANGULAR GEOMETRY BY FINITE VOLUME METHODS
AU - Ain, Khusnul
AU - Kurniadi, Deddy
AU - Ulum, Mokhamad Fakhrul
AU - Choridah, Lina
AU - Mukhayyar, Utriweni
AU - Garnadi, Agah D.
AU - Setyawan, Nurhuda Hendra
AU - Ariwanto, Bayu
N1 - Publisher Copyright:
© 2022 Penerbit UTM Press.
PY - 2022/3
Y1 - 2022/3
N2 - Electrical impedance tomography (EIT) is a non-invasive technique for imaging the electrical conductivity and permittivity in the body by measuring the electrical potential on the surface. One of the EIT applications in the medical field is breast cancer detection. The study proposed a rectangular geometry EIT multi-frequency device based on the Finite Volume Method (FVM) reconstruction method. This device can be used to complement mammography images into dual EIT-mammography modalities. The EIT device built of DDS AD9850 as a programmable multi-frequency sinusoidal generator, AD620 as instrument amplifier, AD536 as an AC converter, and ADS1115 as an ADC 16 bit. These devices can scan at the maximum frequency of 100 kHz. The device has been tested with a phantom of distilled water and carrots in the center and on the sides. The reconstruction methods one step different frequency produces a rectangular geometric image with anomalies in the depth and at the surface clearly.
AB - Electrical impedance tomography (EIT) is a non-invasive technique for imaging the electrical conductivity and permittivity in the body by measuring the electrical potential on the surface. One of the EIT applications in the medical field is breast cancer detection. The study proposed a rectangular geometry EIT multi-frequency device based on the Finite Volume Method (FVM) reconstruction method. This device can be used to complement mammography images into dual EIT-mammography modalities. The EIT device built of DDS AD9850 as a programmable multi-frequency sinusoidal generator, AD620 as instrument amplifier, AD536 as an AC converter, and ADS1115 as an ADC 16 bit. These devices can scan at the maximum frequency of 100 kHz. The device has been tested with a phantom of distilled water and carrots in the center and on the sides. The reconstruction methods one step different frequency produces a rectangular geometric image with anomalies in the depth and at the surface clearly.
KW - Breast cancer
KW - Electrical impedance tomography
KW - Finite volume methods
KW - Multi frequency
KW - Rectangular geometry
UR - http://www.scopus.com/inward/record.url?scp=85127405295&partnerID=8YFLogxK
U2 - 10.11113/jurnalteknologi.v84.16936
DO - 10.11113/jurnalteknologi.v84.16936
M3 - Article
AN - SCOPUS:85127405295
SN - 0127-9696
VL - 84
SP - 9
EP - 15
JO - Jurnal Teknologi (Sciences and Engineering)
JF - Jurnal Teknologi (Sciences and Engineering)
IS - 2
ER -