TY - JOUR
T1 - Development and validation of HPLC method for determination of S-phenylmercapturic acid (S-PMA) in urine
AU - Purwanto, Djoko Agus
AU - Primaharinastiti, Riesta
AU - Annuryanti, Febri
PY - 2014
Y1 - 2014
N2 - Objective: The aim of this study is to obtain the optimum condition of HPLC method for the determination of benzene metabolite, S-phenyl mercapturic acid (S-PMA), in urine samples. Methods: Liquid-liquid extraction (LLE) was used as sample preparation method for urine sample. HPLC analysis was performed using Hypersil ODS column 125 x 4 mm ID, 5 μm, the column temperature 25°C and the DAD detector was set at wavelength of 205 nm. Results: Optimum separation was accomplished using gradient system with eluent consists of methanol and phosphate buffer pH 3. The result showed linear correlation with a regression coefficient (r) = 0.994. The detection and quantification limit of S-PMA were 0.7832 ±0.081;} 0.0329 μg/mL and 2.6108 ±0.0940 μg/mL, respectively. The recovery of the method was 88.34 - 117.16% with a mean of 99.96% and coefficient variation (CV) = 8.98%. Conclusion: The proposed method has met the acceptance criteria for validation. The method is simple, fast, and has reproducible recoveries. Therefore, this method can be used for routine analysis of S-PMA.
AB - Objective: The aim of this study is to obtain the optimum condition of HPLC method for the determination of benzene metabolite, S-phenyl mercapturic acid (S-PMA), in urine samples. Methods: Liquid-liquid extraction (LLE) was used as sample preparation method for urine sample. HPLC analysis was performed using Hypersil ODS column 125 x 4 mm ID, 5 μm, the column temperature 25°C and the DAD detector was set at wavelength of 205 nm. Results: Optimum separation was accomplished using gradient system with eluent consists of methanol and phosphate buffer pH 3. The result showed linear correlation with a regression coefficient (r) = 0.994. The detection and quantification limit of S-PMA were 0.7832 ±0.081;} 0.0329 μg/mL and 2.6108 ±0.0940 μg/mL, respectively. The recovery of the method was 88.34 - 117.16% with a mean of 99.96% and coefficient variation (CV) = 8.98%. Conclusion: The proposed method has met the acceptance criteria for validation. The method is simple, fast, and has reproducible recoveries. Therefore, this method can be used for routine analysis of S-PMA.
KW - HPLC
KW - S-phenylmercapturic acid
KW - Urine
UR - http://www.scopus.com/inward/record.url?scp=84901933353&partnerID=8YFLogxK
M3 - Article
AN - SCOPUS:84901933353
SN - 0975-1491
VL - 6
SP - 305
EP - 308
JO - International Journal of Pharmacy and Pharmaceutical Sciences
JF - International Journal of Pharmacy and Pharmaceutical Sciences
IS - 5
ER -