TY - JOUR
T1 - Comparison of Calcified Plaque Volume in Coronary Arteries using Filtered Back Projection and Intelli IP Advanced at CT-scan 128 Slice
AU - Pratama, Naufal Arya
AU - Muqmiroh, Lailatul
AU - Sari, Amillia Kartika
AU - Ferriastuti, Widiana
AU - Syivasari, Falentina
AU - Muhaimin,
AU - Prassetyo, Sidarta
AU - Nguyen, Cong Tien
AU - Phuong, Phan Anh
AU - Luu, Vu Dang
N1 - Publisher Copyright:
© 2023 by the authors. Licensee Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/)
PY - 2023
Y1 - 2023
N2 - Calcified plaque has a major effect on increasing plaque volume which can increase the risk of Coronary Artery Disease (CAD). The use of Filtered Back Projection (FBP) on CT-scans still has flaws in terms of image quality that can result in errors in the calculation of plaque volume. Intelli IP Advanced is hitachi CT-scan’s Iterative Reconstruction (IR) type and can improve image quality compared to FBP. The purpose of this study is to find out the comparison of calcified plaque volume in coronary arteries using FBP and Intelli IP Advanced. This study used 38 samples of coronary artery blood vessels that had calcified plaque and reconstructed using the reconstruction of FBP and Intelli IP Advanced algorithms (Levels 1-3). Plaque calculation is done automatically using aquarius intuition edition application on CT-scan Hitachi SCENARIA 128 Slice. The results in this study found significant differences (p < 0.05) in calcified plaque volume results with the use of FBP and Intelli IP Advanced algorithm reconstruction (Levels 1-3). However, significant differences are found only in algorithm reconstruction pairs (Intelli IP Advanced Level 1 and Level 3) that have a p < 0.05.
AB - Calcified plaque has a major effect on increasing plaque volume which can increase the risk of Coronary Artery Disease (CAD). The use of Filtered Back Projection (FBP) on CT-scans still has flaws in terms of image quality that can result in errors in the calculation of plaque volume. Intelli IP Advanced is hitachi CT-scan’s Iterative Reconstruction (IR) type and can improve image quality compared to FBP. The purpose of this study is to find out the comparison of calcified plaque volume in coronary arteries using FBP and Intelli IP Advanced. This study used 38 samples of coronary artery blood vessels that had calcified plaque and reconstructed using the reconstruction of FBP and Intelli IP Advanced algorithms (Levels 1-3). Plaque calculation is done automatically using aquarius intuition edition application on CT-scan Hitachi SCENARIA 128 Slice. The results in this study found significant differences (p < 0.05) in calcified plaque volume results with the use of FBP and Intelli IP Advanced algorithm reconstruction (Levels 1-3). However, significant differences are found only in algorithm reconstruction pairs (Intelli IP Advanced Level 1 and Level 3) that have a p < 0.05.
KW - Calcified plaque
KW - Filtered back projection
KW - Intelli IP Аdvanced
UR - http://www.scopus.com/inward/record.url?scp=85153785827&partnerID=8YFLogxK
U2 - 10.7546/IJBA.2023.27.1.000878
DO - 10.7546/IJBA.2023.27.1.000878
M3 - Article
AN - SCOPUS:85153785827
SN - 1314-1902
VL - 27
SP - 15
EP - 24
JO - International Journal Bioautomation
JF - International Journal Bioautomation
IS - 1